Portable · Air-Water Cooled · 2000°C

Portable High Temperature Endoscope for Furnace Inspection

Inspect refractory erosion, flame behaviour and furnace conditions in real time — without shutdown.

  • Up to 2000°C furnace environment
  • Air + water cooling protection
  • Dual viewing angle (0° / 90°)
  • Portable field deployment
  • Real-time video inspection

Place 1.mp4 in the site root to play the furnace inspection video here.

01 / Why Portable Inspection

See Inside Operating Furnaces Without Shutdown

The probe is inserted through an existing furnace port while the cooling system protects the optics from extreme heat. Inspect live, during production. Operators can check:

Refractory erosion Brick displacement Hot spots Flame behaviour Material movement Furnace crown condition
Portable high temperature endoscope assembly
02 / Key Advantages

Why It Pays Off

Real-Time Inspection

Observe furnace condition live during production.

Extended Furnace Life

Detect refractory degradation before failure.

Portable Deployment

Move between multiple furnace locations.

Reduce Shutdown Cost

Make maintenance decisions on actual conditions.

03 / Applications

Inspection Applications

Three-layer cooling structure cutaway
04 / Cooling Technology

Air + Water Dual Cooling Protection

Water Cooling Jacket

Circulating water on the outer layer removes radiant furnace heat.

Air Cooling Channel

Compressed air on the inner layer protects the camera and lens.

Air Curtain Protection

Air blows out at the pinhole to keep dust and hot particles off the lens.

05 / Specifications

Technical Specifications

Model DIA55MM — portable air-water cooled configuration.

Furnace temperature2000 °C
Probe diameterØ55 mm
Probe length1100 mm standard · custom on request
Viewing angle0° direct + 90° side (60° optional)
LensSapphire pinhole · Ø25 mm · 1 mm port
CameraDSLR · CMOS · approx. 20.2 MP · JPEG + RAW
CoolingAir + Water (3-layer protective cover)
Air requirements0.3 MPa · ≥ 0.3 m³/min (instrument air) · ≤ 35 °C
Water requirements0.1–0.4 MPa differential · ≥ 30 L/min · ≤ 35 °C
OperationPortable · online, no shutdown
Data sheetRequest full PDF data sheet →
06 / Inspection Results

What Operators Can Detect

Refractory cracks
Refractory Cracks
Brick erosion
Brick Erosion
Flame distribution
Flame Distribution
Material surface
Material Surface
07 / Questions

FAQ

Can inspection be done without shutdown?

Yes. The cooled probe is inserted through an existing furnace port while the furnace runs — inspection is fully online, no cool-down required.

What cooling media are required?

Compressed (instrument) air at 0.3 MPa, ≥0.3 m³/min, and circulating water at 0.1–0.4 MPa differential, ≥30 L/min, both with inlet temperature ≤35°C.

Can probe length be customized?

The standard probe is Ø55 mm × 1100 mm. Other lengths and diameters are available on request to match your furnace wall and port.

How long can continuous inspection last?

With cooling air and water continuously supplied, the probe can remain in the furnace for extended continuous inspection. Duration depends on furnace temperature and a stable cooling supply.

Get Started

Need a Furnace Inspection Solution?

Send us your furnace temperature, opening size and the area you need to observe — we'll recommend the right configuration.